Yildirim Mutaf, PhD
Clinical Associate Professor
Boston University School of Medicine
Dept of Radiation Oncology

PhD, Stony Brook University
MA, Stony Brook University


Publications listed below are automatically derived from MEDLINE/PubMed and other sources, which might result in incorrect or missing publications. Faculty can login to make corrections and additions.

  1. Chen S, Le Q, Mutaf Y, Lu W, Nichols EM, Yi BY, Leven T, Prado KL, D''Souza WD. Feasibility of CBCT-based dose with a patient-specific stepwise HU-to-density curve to determine time of replanning. J Appl Clin Med Phys. 2017 Sep; 18(5):64-69. PMID: 28703475.
  2. Snider JW, Mutaf Y, Nichols E, Hall A, Vadnais P, Regine WF, Feigenberg SJ. Projected Improvements in Accelerated Partial Breast Irradiation Using a Novel Breast Stereotactic Radiotherapy Device: A Dosimetric Analysis. Technol Cancer Res Treat. 2017 Jan 01; 1533034617718961. PMID: 28705082.
  3. Snider 3rd JW, Mutaf Y, Nichols E, Hall A, Vadnais P, Regine WF, Feigenberg SJ. Dosimetric Improvements with a Novel Breast Stereotactic Radiotherapy Device for Delivery of Preoperative Partial-Breast Irradiation. Oncology. 2017; 92(1):21-30. PMID: 27898429; DOI: 10.1159/000449388;.
  4. Ödén J, Toma-Dasu I, Yu CX, Feigenberg SJ, Regine WF, Mutaf YD. Dosimetric comparison between intra-cavitary breast brachytherapy techniques for accelerated partial breast irradiation and a novel stereotactic radiotherapy device for breast cancer: GammaPod™. Phys Med Biol. 2013 Jul 7; 58(13):4409-21. PMID: 23743718; DOI: 10.1088/0031-9155/58/13/4409;.
  5. Mutaf YD, Zhang J, Yu CX, Yi BY, Prado K, D'Souza WD, Regine WF, Feigenberg SJ. Dosimetric and geometric evaluation of a novel stereotactic radiotherapy device for breast cancer: the GammaPod™. Med Phys. 2013 Apr; 40(4):041722. PMID: 23556892; DOI: 10.1118/1.4794477;.
  6. Mutaf Y, Yu C, Zhang J, Yi B, Prado K, D''Souza W, Regine W, Feigenberg S. SU-E-T-399: Dosimetric and Geometric Evaluation of a Novel Stereotactic Radiotherapy Device for Breast Cancer: The GammaPod. Med Phys. 2012 Jun; 39(6Part16):3796. PMID: 28517176.
  7. Yang X, Reese A, Mutaf Y, Yi B. SU-E-J-207: Compensation of Target Distortion of Pancreatic Tumor in Free-Breathing CT Using 4D Contour Propagation. Med Phys. 2012 Jun; 39(6Part9):3700. PMID: 28519049.
  8. Mutaf YD, Scicutella CJ, Michalski D, Fallon K, Brandner ED, Bednarz G, Huq MS. A simulation study of irregular respiratory motion and its dosimetric impact on lung tumors. Phys Med Biol. 2011 Feb 7; 56(3):845-59. PMID: 21242627; DOI: 10.1088/0031-9155/56/3/019;.
  9. Mutaf YD, Brinkmann DH. An investigation of temporal resolution parameters in cine-mode four-dimensional computed tomography acquisition. J Appl Clin Med Phys. 2008 Oct 29; 9(4):2819. PMID: 19020488.
  10. Mutaf YD, Brinkmann DH. Optimization of internal margin to account for dosimetric effects of respiratory motion. Int J Radiat Oncol Biol Phys. 2008 Apr 1; 70(5):1561-70. PMID: 18374230; DOI: 10.1016/j.ijrobp.2007.12.025;.
Showing 10 of 46 results. Show More

This graph shows the total number of publications by year, by first, middle/unknown, or last author.

Bar chart showing 46 publications over 12 distinct years, with a maximum of 19 publications in 2005

YearPublications
20021
20031
20044
200519
20069
20072
20082
20111
20122
20132
20161
20172
Contact for Mentoring:


830 Harrison Ave
Boston MA 02118
Google Map


Mutaf's Networks
Click the "See All" links for more information and interactive visualizations
Concepts
_
Similar People
_
Same Department